| if ARCH_S3C2410 | |
| menu "S3C24XX Implementations" | |
| config MACH_ANUBIS | |
| bool "Simtec Electronics ANUBIS" | |
| select CPU_S3C2440 | |
| help | |
| Say Y gere if you are using the Simtec Electronics ANUBIS | |
| development system | |
| config MACH_OSIRIS | |
| bool "Simtec IM2440D20 (OSIRIS) module" | |
| select CPU_S3C2440 | |
| help | |
| Say Y here if you are using the Simtec IM2440D20 module, also | |
| known as the Osiris. | |
| config ARCH_BAST | |
| bool "Simtec Electronics BAST (EB2410ITX)" | |
| select CPU_S3C2410 | |
| select ISA | |
| help | |
| Say Y here if you are using the Simtec Electronics EB2410ITX | |
| development board (also known as BAST) | |
| Product page: <http://www.simtec.co.uk/products/EB2410ITX/>. | |
| config BAST_PC104_IRQ | |
| bool "BAST PC104 IRQ support" | |
| depends on ARCH_BAST | |
| default y | |
| help | |
| Say Y here to enable the PC104 IRQ routing on the | |
| Simtec BAST (EB2410ITX) | |
| config ARCH_H1940 | |
| bool "IPAQ H1940" | |
| select CPU_S3C2410 | |
| help | |
| Say Y here if you are using the HP IPAQ H1940 | |
| <http://www.handhelds.org/projects/h1940.html>. | |
| config MACH_N30 | |
| bool "Acer N30" | |
| select CPU_S3C2410 | |
| help | |
| Say Y here if you are using the Acer N30 | |
| <http://zoo.weinigel.se/n30>. | |
| config MACH_SMDK | |
| bool | |
| help | |
| Common machine code for SMDK2410 and SMDK2440 | |
| config ARCH_SMDK2410 | |
| bool "SMDK2410/A9M2410" | |
| select CPU_S3C2410 | |
| select MACH_SMDK | |
| help | |
| Say Y here if you are using the SMDK2410 or the derived module A9M2410 | |
| <http://www.fsforth.de> | |
| config ARCH_S3C2440 | |
| bool "SMDK2440" | |
| select CPU_S3C2440 | |
| select MACH_SMDK | |
| help | |
| Say Y here if you are using the SMDK2440. | |
| config SMDK2440_CPU2440 | |
| bool "SMDK2440 with S3C2440 cpu module" | |
| depends on ARCH_S3C2440 | |
| default y if ARCH_S3C2440 | |
| select CPU_S3C2440 | |
| config SMDK2440_CPU2442 | |
| bool "SMDM2440 with S3C2442 cpu module" | |
| depends on ARCH_S3C2440 | |
| select CPU_S3C2442 | |
| config MACH_VR1000 | |
| bool "Thorcom VR1000" | |
| select CPU_S3C2410 | |
| help | |
| Say Y here if you are using the Thorcom VR1000 board. | |
| This linux port is currently being maintained by Simtec, on behalf | |
| of Thorcom. Any queries, please contact Thorcom first. | |
| config MACH_RX3715 | |
| bool "HP iPAQ rx3715" | |
| select CPU_S3C2440 | |
| help | |
| Say Y here if you are using the HP iPAQ rx3715. | |
| See <http://www.handhelds.org/projects/rx3715.html> for more | |
| information on this project | |
| config MACH_OTOM | |
| bool "NexVision OTOM Board" | |
| select CPU_S3C2410 | |
| help | |
| Say Y here if you are using the Nex Vision OTOM board | |
| config MACH_NEXCODER_2440 | |
| bool "NexVision NEXCODER 2440 Light Board" | |
| select CPU_S3C2440 | |
| help | |
| Say Y here if you are using the Nex Vision NEXCODER 2440 Light Board | |
| endmenu | |
| config CPU_S3C2410 | |
| bool | |
| depends on ARCH_S3C2410 | |
| help | |
| Support for S3C2410 and S3C2410A family from the S3C24XX line | |
| of Samsung Mobile CPUs. | |
| config CPU_S3C244X | |
| bool | |
| depends on ARCH_S3C2410 && (CPU_S3C2440 || CPU_S3C2442) | |
| help | |
| Support for S3C2440 and S3C2442 Samsung Mobile CPU based systems. | |
| config CPU_S3C2440 | |
| bool | |
| depends on ARCH_S3C2410 | |
| select CPU_S3C244X | |
| help | |
| Support for S3C2440 Samsung Mobile CPU based systems. | |
| config CPU_S3C2442 | |
| bool | |
| depends on ARCH_S3C2420 | |
| select CPU_S3C244X | |
| help | |
| Support for S3C2442 Samsung Mobile CPU based systems. | |
| comment "S3C2410 Boot" | |
| config S3C2410_BOOT_WATCHDOG | |
| bool "S3C2410 Initialisation watchdog" | |
| depends on ARCH_S3C2410 && S3C2410_WATCHDOG | |
| help | |
| Say y to enable the watchdog during the kernel decompression | |
| stage. If the kernel fails to uncompress, then the watchdog | |
| will trigger a reset and the system should restart. | |
| Although this uses the same hardware unit as the kernel watchdog | |
| driver, it is not a replacement for it. If you use this option, | |
| you will have to use the watchdg driver to either stop the timeout | |
| or restart it. If you do not, then your kernel will reboot after | |
| startup. | |
| The driver uses a fixed timeout value, so the exact time till the | |
| system resets depends on the value of PCLK. The timeout on an | |
| 200MHz s3c2410 should be about 30 seconds. | |
| config S3C2410_BOOT_ERROR_RESET | |
| bool "S3C2410 Reboot on decompression error" | |
| depends on ARCH_S3C2410 | |
| help | |
| Say y here to use the watchdog to reset the system if the | |
| kernel decompressor detects an error during decompression. | |
| comment "S3C2410 Setup" | |
| config S3C2410_DMA | |
| bool "S3C2410 DMA support" | |
| depends on ARCH_S3C2410 | |
| help | |
| S3C2410 DMA support. This is needed for drivers like sound which | |
| use the S3C2410's DMA system to move data to and from the | |
| peripheral blocks. | |
| config S3C2410_DMA_DEBUG | |
| bool "S3C2410 DMA support debug" | |
| depends on ARCH_S3C2410 && S3C2410_DMA | |
| help | |
| Enable debugging output for the DMA code. This option sends info | |
| to the kernel log, at priority KERN_DEBUG. | |
| Note, it is easy to create and fill the log buffer in a small | |
| amount of time, as well as using an significant percentage of | |
| the CPU time doing so. | |
| config S3C2410_PM_DEBUG | |
| bool "S3C2410 PM Suspend debug" | |
| depends on ARCH_S3C2410 && PM | |
| help | |
| Say Y here if you want verbose debugging from the PM Suspend and | |
| Resume code. See <file:Documentation/arm/Samsung-S3C24XX/Suspend.txt> | |
| for more information. | |
| config S3C2410_PM_CHECK | |
| bool "S3C2410 PM Suspend Memory CRC" | |
| depends on ARCH_S3C2410 && PM && CRC32 | |
| help | |
| Enable the PM code's memory area checksum over sleep. This option | |
| will generate CRCs of all blocks of memory, and store them before | |
| going to sleep. The blocks are then checked on resume for any | |
| errors. | |
| config S3C2410_PM_CHECK_CHUNKSIZE | |
| int "S3C2410 PM Suspend CRC Chunksize (KiB)" | |
| depends on ARCH_S3C2410 && PM && S3C2410_PM_CHECK | |
| default 64 | |
| help | |
| Set the chunksize in Kilobytes of the CRC for checking memory | |
| corruption over suspend and resume. A smaller value will mean that | |
| the CRC data block will take more memory, but wil identify any | |
| faults with better precision. | |
| config PM_SIMTEC | |
| bool | |
| depends on PM && (ARCH_BAST || MACH_VR1000) | |
| default y | |
| config S3C2410_LOWLEVEL_UART_PORT | |
| int "S3C2410 UART to use for low-level messages" | |
| default 0 | |
| help | |
| Choice of which UART port to use for the low-level messages, | |
| such as the `Uncompressing...` at start time. The value of | |
| this configuration should be between zero and two. The port | |
| must have been initialised by the boot-loader before use. | |
| Note, this does not affect the port used by the debug messages, | |
| which is a separate configuration. | |
| endif |