blob: 27a45fe5ecf17ae96869c5a5ae9027898af75c6d [file] [log] [blame]
--------------------------------------------------------------------------
= Zynq UltraScale+ MPSoC reset driver binding =
--------------------------------------------------------------------------
The Zynq UltraScale+ MPSoC has several different resets.
See Chapter 36 of the Zynq UltraScale+ MPSoC TRM (UG) for more information
about zynqmp resets.
Please also refer to reset.txt in this directory for common reset
controller binding usage.
Required Properties:
- compatible: "xlnx,zynqmp-reset"
- #reset-cells: Specifies the number of cells needed to encode reset
line, should be 1
-------
Example
-------
firmware {
zynqmp_firmware: zynqmp-firmware {
compatible = "xlnx,zynqmp-firmware";
method = "smc";
zynqmp_reset: reset-controller {
compatible = "xlnx,zynqmp-reset";
#reset-cells = <1>;
};
};
};
Specifying reset lines connected to IP modules
==============================================
Device nodes that need access to reset lines should
specify them as a reset phandle in their corresponding node as
specified in reset.txt.
For list of all valid reset indicies see
<dt-bindings/reset/xlnx-zynqmp-resets.h>
Example:
serdes: zynqmp_phy@fd400000 {
...
resets = <&zynqmp_reset ZYNQMP_RESET_SATA>;
reset-names = "sata_rst";
...
};