| TI BQ24190 Li-Ion Battery Charger |
| |
| Required properties: |
| - compatible: contains one of the following: |
| * "ti,bq24190" |
| * "ti,bq24192i" |
| - reg: integer, I2C address of the charger. |
| - interrupts[-extended]: configuration for charger INT pin. |
| |
| Optional properties: |
| - monitored-battery: phandle of battery characteristics devicetree node |
| The charger uses the following battery properties: |
| + precharge-current-microamp: maximum charge current during precharge |
| phase (typically 20% of battery capacity). |
| + charge-term-current-microamp: a charge cycle terminates when the |
| battery voltage is above recharge threshold, and the current is below |
| this setting (typically 10% of battery capacity). |
| See also Documentation/devicetree/bindings/power/supply/battery.txt |
| - ti,system-minimum-microvolt: when power is connected and the battery is below |
| minimum system voltage, the system will be regulated above this setting. |
| |
| Notes: |
| - Some circuit boards wire the chip's "OTG" pin high (enabling 500mA default |
| charge current on USB SDP ports, among other features). To simulate this on |
| boards that wire the pin to a GPIO, set a gpio-hog. |
| |
| Example: |
| |
| bat: battery { |
| compatible = "simple-battery"; |
| precharge-current-microamp = <256000>; |
| charge-term-current-microamp = <128000>; |
| // etc. |
| }; |
| |
| bq24190: charger@6a { |
| compatible = "ti,bq24190"; |
| reg = <0x6a>; |
| interrupts-extended = <&gpiochip 10 IRQ_TYPE_EDGE_FALLING>; |
| monitored-battery = <&bat>; |
| ti,system-minimum-microvolt = <3200000>; |
| }; |
| |
| &twl_gpio { |
| otg { |
| gpio-hog; |
| gpios = <6 0>; |
| output-high; |
| line-name = "otg-gpio"; |
| }; |
| }; |