| Kernel driver sht21 | 
 | =================== | 
 |  | 
 | Supported chips: | 
 |   * Sensirion SHT21 | 
 |     Prefix: 'sht21' | 
 |     Addresses scanned: none | 
 |     Datasheet: Publicly available at the Sensirion website | 
 |     http://www.sensirion.com/en/pdf/product_information/Datasheet-humidity-sensor-SHT21.pdf | 
 |  | 
 |   * Sensirion SHT25 | 
 |     Prefix: 'sht21' | 
 |     Addresses scanned: none | 
 |     Datasheet: Publicly available at the Sensirion website | 
 |     http://www.sensirion.com/en/pdf/product_information/Datasheet-humidity-sensor-SHT25.pdf | 
 |  | 
 | Author: | 
 |   Urs Fleisch <urs.fleisch@sensirion.com> | 
 |  | 
 | Description | 
 | ----------- | 
 |  | 
 | The SHT21 and SHT25 are humidity and temperature sensors in a DFN package of | 
 | only 3 x 3 mm footprint and 1.1 mm height. The difference between the two | 
 | devices is the higher level of precision of the SHT25 (1.8% relative humidity, | 
 | 0.2 degree Celsius) compared with the SHT21 (2.0% relative humidity, | 
 | 0.3 degree Celsius). | 
 |  | 
 | The devices communicate with the I2C protocol. All sensors are set to the same | 
 | I2C address 0x40, so an entry with I2C_BOARD_INFO("sht21", 0x40) can be used | 
 | in the board setup code. | 
 |  | 
 | sysfs-Interface | 
 | --------------- | 
 |  | 
 | temp1_input - temperature input | 
 | humidity1_input - humidity input | 
 |  | 
 | Notes | 
 | ----- | 
 |  | 
 | The driver uses the default resolution settings of 12 bit for humidity and 14 | 
 | bit for temperature, which results in typical measurement times of 22 ms for | 
 | humidity and 66 ms for temperature. To keep self heating below 0.1 degree | 
 | Celsius, the device should not be active for more than 10% of the time, | 
 | e.g. maximum two measurements per second at the given resolution. | 
 |  | 
 | Different resolutions, the on-chip heater, using the CRC checksum and reading | 
 | the serial number are not supported yet. |