ibmpex: correct power use multipliers for QS2x blade
The QS2x blades ships with v2.54 of the firmware, which use the same
multiplier for all power meters.
Signed-off-by: Darrick J. Wong <djwong@us.ibm.com>
Cc: Mark M. Hoffman <mhoffman@lightlink.com>
Signed-off-by: Andrew Morton <akpm@linux-foundation.org>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
diff --git a/drivers/hwmon/ibmpex.c b/drivers/hwmon/ibmpex.c
index 9c9cdb0..db551d8 100644
--- a/drivers/hwmon/ibmpex.c
+++ b/drivers/hwmon/ibmpex.c
@@ -327,10 +327,14 @@
return 0;
}
-static int power_sensor_multiplier(const char *sensor_id, int len)
+static int power_sensor_multiplier(struct ibmpex_bmc_data *data,
+ const char *sensor_id, int len)
{
int i;
+ if (data->sensor_major == 2)
+ return 1000000;
+
for (i = PEX_SENSOR_TYPE_LEN; i < len - 1; i++)
if (!memcmp(&sensor_id[i], watt_sensor_sig, PEX_MULT_LEN))
return 1000000;
@@ -398,8 +402,9 @@
num_power++;
sensor_counter = num_power;
data->sensors[i].multiplier =
- power_sensor_multiplier(data->rx_msg_data,
- data->rx_msg_len);
+ power_sensor_multiplier(data,
+ data->rx_msg_data,
+ data->rx_msg_len);
} else if (is_temp_sensor(data->rx_msg_data,
data->rx_msg_len)) {
sensor_type = TEMP_SENSOR;